FAN ASPIRATED MET4A BROADBAND METEOROLOGICAL MEASUREMENT SYSTEM

 To download MET4A data sheet click here   
 

Fan - Aspirated MET4A

  Performance
  • Pressure Accuracy better than  ±0.08 hPa from 500 to
    1100 hPa
  • Temperature Accuracy better than ±0.2 deg C from -50 to +60 deg C
  • Relative Humidity Accuracy better than ±2 Percent from 0 to 100 %RH at 25 deg C.
  • Humidity Recovery Time after Saturation is less that 20 seconds.
  Features
  • Fan-Aspirated
  • High Performance Pressure Port (Wind Insensitive)
  • RS-232 and RS-485 Bi-Directional Interface
  • Instrument Status LED Indicators (Power, Transmit, Receive)
  • 3 Year Warranty on Barometer Stability
  • ISO 9001:2000 Quality System - NIST Traceable - CE Compliant
 Optional Configurations
  • Barometric Functions
  • Data Logger
  Applications
  • GPS Meteorology
  • Environmental Monitoring
  • Laboratory and Field Portable Calibrators
  • Automated Surface Observation Systems
  • Ground Based Altimeter Setting Indicators
  General

The MET4A is a Fan-Aspirated Meteorological Measurement System that provides high accuracy data from barometric pressure, temperature and relative humidity sensors. Pressure resolution is better than 1 microbar with a total accuracy of better than ±0.08 hPa over the extended barometric range of 500 to 1100 hPa. Temperature resolution is 0.01 degrees C with a total accuracy of better than ±0.2 degree C over the full temperature range of –50 to +60 degrees C. Relative humidity performance is better than ±2% at 25 degrees C and the recovery time after 100% RH saturation is less than 20 seconds. Desirable characteristics include  durable weather proof packaging, no warm up time, high reliability and long term stability. Optional configurations include Barometric Functions (Altimeter Setting, Station pressure, Field pressure, Sea level pressure, Density Altitude, Pressure Altitude, QNH, QFE and WMO Pressure Tendency Codes) and/or Data Logging. The measurement suite can be interfaced with Computer Systems, GPS Receivers and External Loggers.

An internal Digiquartz® pressure transducer, precision temperature/humidity probe and microprocessor-based electronics provide the measurement and communications capabilities Measurement data is accessed via RS232 or RS-485 serial ports. An external status panel monitors power status and RS-232/RS485 communication.

The MET4A features the DigiPort high-performance barometric pressure port. It is designed to dramatically reduce barometric pressure measurement errors in the presence of wind.

Air temperature and humidity measurements are provided by a single probe. The probe is fully calibrated and self contained, providing easy plug and play interchangeability. The probe is readily accessed by the user for field replacement.

The air temperature/humidity probe is housed within  a solar shield. The purpose of the solar radiation shield is to minimize air temperature measurement errors caused by exposure to direct sunlight. The MET4A features a multi-chamber, fan-aspirated solar shield for superior immunity to temperature measurement errors caused by solar radiation.

The MET4A is designed for easy and convenient mounting to masts, tubing and other structures. Mounting hardware is included for easy system integration

The Digiquartz® barometer used in the MET4A has a 3-year stability warranty of better that 0.1 hPa per year and includes a limited 5-year warranty with the first 2-years covered at 100%. The System includes a limited one-year warranty. The RH and Temperature probe is field replaceable and barometer performance can be verified in the field using the Paroscientific Model 765-16B Portable Pressure Standard and DigiPort High Performance Pressure Port.

 

  Related Links